Overview

The TX7004 intelligent addressable fire alarm control panel comprise of a range of analogue addressable, microprocessor based fire alarm control equipment to offer flexibility in both design and operation. The System is modular concept for easy tailoring of system design, to meet the full requirements of the project. The TX7004 intelligent addressable fire alarm control panel is designed and manufactured to meet the requirement of BS EN54 Part 2&4.


The TX7004 intelligent addressable fire alarm control panel is designed to provide early warning fire detection, to quickly identify the location of fire and provide user definable text informing the occupants of the building of potential smoke spread. Simultaneously, the TX7004 will alert and evacuate the occupants, and control all necessary auxiliary command functions such as 
elevator control, air handling shut down, gas shut off & damper control, as per the cause and effects requirements configured though Command Builder Set-up.

Feature and Benefits

• Certified EN54-2:1997 +A1:2006, EN54-4:1997 + A1:2002 + A2:2006 
• LPCB Approved 
• Using advance microprocessor technology with Large memory capacity
• Enhance user interface combining LCD Touch screen and keypad access
• Support real time visual algorithm 
• Enhance false alarm prevention 
• Keypad and PC programming 
• Built-in Multiple interface protocol such as USB/Ethernet/CanBus/ Serial/RS485(Available only in TX7004/4 Panel)
• Support Loop Powered devices for extra saving on cable cost
• Built-In Printer and 160 LED Zones Indicators

Commissioning Advantage

  • Compliance EN54-2 & EN54-4
  • Using advance microprocessor technology with Large memory capacity
  • Enhance user interface combining LCD Touch screen and keypad access
  • Support real time visual algorithm
  • Enhance false alarm prevention
  • Keypad and PC programming
  • Support Multiple interface protocol such as USB/Ethernet/CanBus/Serial/RS485/Fiber Optic
  • Support Loop Powered devices for extra saving on cable cost
  • Built-In Printer and 30 LED Zones Indicators
  • Auto Enrolling of Devices
  • Monitor device mismatch and dual address conflict
  • Command Builder to create requirements for fire event scenario
  • With Loop protection against power surge
  • One-man test with On/Off sounder
  • Programming Protection

Technical Specification

Listed : LPCB / CE-CPR
Certified : EN54-2:1997 +A1:2006, EN54-4:1997 + A1:2002 + A2:2006

 

Power RatingInput

Voltage : 240VAC +10%-15%, 50/60Hz
Input Current Consumption : 1 A
PSU Output to CIE : 24.5 to 28.5 VDC
Batteries : 2 x 12V / 28AH

 

Networking and Interfaces
Panel to panel communication : Can Bus [loop]
Number of Panels : 512 
Interface Port : USB, RS485 Serial, RS232 Serial, Ethernet


System Capacity
Memory [Non-Volatile]  : 1000 Fire Events, 10,000 General Event 
Zones : 3,000 programmable 
Total Group : 3,000 programmable 
Sounder Group : 1,000 programmable 
Common Group:  2,000 programmable

 

Loop Specifications 
Protocol/Addressing : T&A, Value range from 1 to 254
No. of Loop : 4 Loop
Protection : Built-in 4kV Surge protection 
Power rating : 16 to 24Vdc 
Cabling : 1.2Km Max Length/2 x 1.5mm²solid core Fire resistance

 

Input/outputs
Programmable Relays : 4 circuits, Normally Open/Close
Programmable Input : 1 Circuit, Power limited 24Vdc (for future use)
Programmable Auxiliary Power : 19 t0 28 VDC (Note: Current Limited)
Fixed Outputs (FPE/Sounder) : 2 Circuits, 18 t0 28 VDC (Note: Current Limited)
Indicator : 24 LED Status/ 160 Zone Indicators
Display : 7” TFT Touch Screen
Keypad : 5 Brigade buttons and Programming Keypad


Material / Color : Flat sheet Metal / with outer glass door, Orange stripe 
Dimension Lx W x H : 530 mm x 490 mm x 135 mm
Weight : 16.70 Kg
Humidity : 0 to 95% Relative Humidity, Non condensing

×